PMID-sentid Pub_year Sent_text comp_official_name comp_offsetprotein_name organism prot_offset 34772633-4 2022 The simplified method presented a wide linear range of nitrite between 0.091 mug mL-1 and 1.47 mug mL-1, a sensitivity of 0.447 Abs mL microg-1, a determination coefficient of 0.998, and a low limit of detection of 0.053 mug mL-1. Nitrites 55-62 L1 cell adhesion molecule Mus musculus 81-94 23099167-4 2013 The linear calibration range for nitrite was 0.04-0.8 mug mL(-1) with a detection limit of 13.6 ng mL(-1) (S/N=3.29). Nitrites 33-40 L1 cell adhesion molecule Mus musculus 58-64 23099167-4 2013 The linear calibration range for nitrite was 0.04-0.8 mug mL(-1) with a detection limit of 13.6 ng mL(-1) (S/N=3.29). Nitrites 33-40 L1 cell adhesion molecule Mus musculus 99-105 23099167-5 2013 The relative standard deviation for ten determinations of 0.1 and 0.4 mug mL(-1) nitrite were 1.38% and 2.01%, respectively. Nitrites 81-88 L1 cell adhesion molecule Mus musculus 74-80 34863604-4 2022 Nitrite exhibited a linear relationship with the grayscale of the gel interface in the range of 0.3-9 mug mL-1 with a detection limit of 0.3 mug mL-1. Nitrites 0-7 L1 cell adhesion molecule Mus musculus 106-110 34863604-4 2022 Nitrite exhibited a linear relationship with the grayscale of the gel interface in the range of 0.3-9 mug mL-1 with a detection limit of 0.3 mug mL-1. Nitrites 0-7 L1 cell adhesion molecule Mus musculus 145-149 34772633-4 2022 The simplified method presented a wide linear range of nitrite between 0.091 mug mL-1 and 1.47 mug mL-1, a sensitivity of 0.447 Abs mL microg-1, a determination coefficient of 0.998, and a low limit of detection of 0.053 mug mL-1. Nitrites 55-62 L1 cell adhesion molecule Mus musculus 99-103 34772633-4 2022 The simplified method presented a wide linear range of nitrite between 0.091 mug mL-1 and 1.47 mug mL-1, a sensitivity of 0.447 Abs mL microg-1, a determination coefficient of 0.998, and a low limit of detection of 0.053 mug mL-1. Nitrites 55-62 L1 cell adhesion molecule Mus musculus 225-229 34772633-8 2022 The developed method was furtherly applied in the determination of nitrite using a developed paper-based analytical device that detected a nitrite concentration of 3 mug mL-1 which is considered by the World Health Organization to be the maximal permissible limit of nitrite in drinking water. Nitrites 67-74 L1 cell adhesion molecule Mus musculus 170-174 34772633-8 2022 The developed method was furtherly applied in the determination of nitrite using a developed paper-based analytical device that detected a nitrite concentration of 3 mug mL-1 which is considered by the World Health Organization to be the maximal permissible limit of nitrite in drinking water. Nitrites 139-146 L1 cell adhesion molecule Mus musculus 170-174 34772633-8 2022 The developed method was furtherly applied in the determination of nitrite using a developed paper-based analytical device that detected a nitrite concentration of 3 mug mL-1 which is considered by the World Health Organization to be the maximal permissible limit of nitrite in drinking water. Nitrites 267-274 L1 cell adhesion molecule Mus musculus 170-174 31064131-7 2019 The calibration graph for nitrites (after oxidation to nitrates) was linear in the range of 0.5-15 microg mL-1 with a correlation coefficient of 0.9972. Nitrites 26-34 L1 cell adhesion molecule Mus musculus 106-110 31064131-9 2019 The nitrate concentrations in the saliva samples were found in the range of 8.98-18.52 mug mL-1, whereas nitrite was in the range of 3.50-5.34 mug mL-1. Nitrites 105-112 L1 cell adhesion molecule Mus musculus 147-151 29291791-2 2018 Nitrite is on-line reduced to volatile nitric oxide (NO) by 1.5% (m/v) ascorbic acid and 1.0 mol L-1 hydrochloric acid. Nitrites 0-7 L1 cell adhesion molecule Mus musculus 97-100 29291791-5 2018 The limit of detection of the proposed method was calculated to be 0.26 mug mL-1 of nitrite by measuring NO emission at 237.0 nm. Nitrites 84-91 L1 cell adhesion molecule Mus musculus 76-80 29291791-6 2018 The calibration curve is linear for the nitrite concentration in the range of 2.0-100.0 mug mL-1 and good precision (2.3%, RSD) is readily achieved for 5.0 mug mL-1 nitrite. Nitrites 40-47 L1 cell adhesion molecule Mus musculus 92-96 29291791-6 2018 The calibration curve is linear for the nitrite concentration in the range of 2.0-100.0 mug mL-1 and good precision (2.3%, RSD) is readily achieved for 5.0 mug mL-1 nitrite. Nitrites 40-47 L1 cell adhesion molecule Mus musculus 160-164 29291791-6 2018 The calibration curve is linear for the nitrite concentration in the range of 2.0-100.0 mug mL-1 and good precision (2.3%, RSD) is readily achieved for 5.0 mug mL-1 nitrite. Nitrites 165-172 L1 cell adhesion molecule Mus musculus 92-96 29291791-6 2018 The calibration curve is linear for the nitrite concentration in the range of 2.0-100.0 mug mL-1 and good precision (2.3%, RSD) is readily achieved for 5.0 mug mL-1 nitrite. Nitrites 165-172 L1 cell adhesion molecule Mus musculus 160-164 29495331-1 2018 A novel fluorescence sensor of NR-beta-CD@AuNPs was prepared for the trace detection of nitrite in quantities as low as 4.25 x 10-3 mug mL-1 in an aqueous medium. Nitrites 88-95 L1 cell adhesion molecule Mus musculus 136-140