PMID-sentid Pub_year Sent_text comp_official_name comp_offsetprotein_name organism prot_offset 23021851-8 2013 Furthermore, the inhibition investigation demonstrates that fisetin and chlorogenic acid can inhibit the M. SssI MTase activity with the IC(50) value of 153.12 and 137.07 muM, respectively. Chlorogenic Acid 72-88 latexin Homo sapiens 171-174 26037533-6 2015 Chlorogenic acid (100 muM) showed inhibitory activity with the inhibitory percentage of 19.8%, while the other compounds showed no inhibitory activity. Chlorogenic Acid 0-16 latexin Homo sapiens 22-25 31196425-5 2019 Under optimized conditions, the fabricated sensor displays two wide linear responses in the ranges of 5.8-733.8 muM and 733.8-2933.8 muM for hydroxylamine, with a rapid response time about 1 s. For chlorogenic acid, the sensor presents linear responses in the ranges of 0.1-2 muM and 2-15 muM, with a high sensitivity of 10.18 muA/muM. Chlorogenic Acid 198-214 latexin Homo sapiens 112-115 31196425-5 2019 Under optimized conditions, the fabricated sensor displays two wide linear responses in the ranges of 5.8-733.8 muM and 733.8-2933.8 muM for hydroxylamine, with a rapid response time about 1 s. For chlorogenic acid, the sensor presents linear responses in the ranges of 0.1-2 muM and 2-15 muM, with a high sensitivity of 10.18 muA/muM. Chlorogenic Acid 198-214 latexin Homo sapiens 133-136 31196425-5 2019 Under optimized conditions, the fabricated sensor displays two wide linear responses in the ranges of 5.8-733.8 muM and 733.8-2933.8 muM for hydroxylamine, with a rapid response time about 1 s. For chlorogenic acid, the sensor presents linear responses in the ranges of 0.1-2 muM and 2-15 muM, with a high sensitivity of 10.18 muA/muM. Chlorogenic Acid 198-214 latexin Homo sapiens 133-136 31196425-5 2019 Under optimized conditions, the fabricated sensor displays two wide linear responses in the ranges of 5.8-733.8 muM and 733.8-2933.8 muM for hydroxylamine, with a rapid response time about 1 s. For chlorogenic acid, the sensor presents linear responses in the ranges of 0.1-2 muM and 2-15 muM, with a high sensitivity of 10.18 muA/muM. Chlorogenic Acid 198-214 latexin Homo sapiens 133-136 31196425-5 2019 Under optimized conditions, the fabricated sensor displays two wide linear responses in the ranges of 5.8-733.8 muM and 733.8-2933.8 muM for hydroxylamine, with a rapid response time about 1 s. For chlorogenic acid, the sensor presents linear responses in the ranges of 0.1-2 muM and 2-15 muM, with a high sensitivity of 10.18 muA/muM. Chlorogenic Acid 198-214 latexin Homo sapiens 133-136