PMID-sentid Pub_year Sent_text comp_official_name comp_offsetprotein_name organism prot_offset 23282767-3 2013 The sensitivities for AA, DA and UA obtained by DPV are 5.39 A m(-2) mM(-1), 0.054 A m(-2) muM(-1) and 0.022 A m(-2) muM(-1), respectively. diperoxovanadate 48-51 PWWP domain containing 3A, DNA repair factor Homo sapiens 117-123 33740190-5 2021 Some parameters such as linear range, sensitivity, and detection limit for reduction peak were obtained as 0.1-140 muM, 1.4154 muA cm-2 muM-1, and 0.03 muM, respectively, by the DPV technique. diperoxovanadate 178-181 PWWP domain containing 3A, DNA repair factor Homo sapiens 136-141 33562228-4 2021 Under optimal conditions, the best analytical performance was obtained with CNT/PMBDES/GCE in 0.04 M BR buffer pH 7.0 in the range 5-100 microM 5-ASA using the DPV method, with an excellent sensitivity of 9.84 muA cm-2 muM-1 (4.9 % RSD, n = 5) and a detection limit (LOD) (3sigma/slope) of 7.7 nM, outclassing most similar sensors found in the literature. diperoxovanadate 160-163 PWWP domain containing 3A, DNA repair factor Homo sapiens 219-224 33179119-3 2020 Such CoMoO4/BCN/SPCE exhibits an ultralow detection limit of 1.6 nM with a concentration range of 0.04-408.9 muM, and high sensitivity of 11.6 muA muM-1 cm-2 by DPV method. diperoxovanadate 161-164 PWWP domain containing 3A, DNA repair factor Homo sapiens 147-152 32880716-7 2020 The DPV response currents are linearly dependent on concentrations of xanthine (Xa) in the range 0.10-20 muM, along with a high sensitivity of 6.84 muA muM-1 cm-2 and very low detection limit of 0.006 muM (S/N = 3) under the optimal working potential of 0.64 V vs. SCE. diperoxovanadate 4-7 PWWP domain containing 3A, DNA repair factor Homo sapiens 152-157 25104572-7 2014 Using the DPV technique, an improved sensitivity and detection limit of 1.94 x 10(-6) A muM(-1) cm(-2) and 17.7 nM are respectively achieved. diperoxovanadate 10-13 PWWP domain containing 3A, DNA repair factor Homo sapiens 88-94 24461828-4 2014 The prepared PMET/ERGO/GCE film exhibits excellent DPV response towards PZM and the reduction peak current increased linearly with respect to PZM concentration in the linear range between 0.4 muM to 1129 muM with a sensitivity of 0.266 muA muM(-1) cm(-2). diperoxovanadate 51-54 PWWP domain containing 3A, DNA repair factor Homo sapiens 240-246 23282767-3 2013 The sensitivities for AA, DA and UA obtained by DPV are 5.39 A m(-2) mM(-1), 0.054 A m(-2) muM(-1) and 0.022 A m(-2) muM(-1), respectively. diperoxovanadate 48-51 PWWP domain containing 3A, DNA repair factor Homo sapiens 91-97 23324449-5 2013 In addition, the detection sensitivities for DA and UA by DPV were 1.03 muA muM(-1) and 2.09 muA muM(-1), respectively, which were much higher than those from a cyclic voltammogram. diperoxovanadate 58-61 PWWP domain containing 3A, DNA repair factor Homo sapiens 76-82 23324449-5 2013 In addition, the detection sensitivities for DA and UA by DPV were 1.03 muA muM(-1) and 2.09 muA muM(-1), respectively, which were much higher than those from a cyclic voltammogram. diperoxovanadate 58-61 PWWP domain containing 3A, DNA repair factor Homo sapiens 97-103