Title : Mathematical model of fetal circulation and oxygen delivery.

Pub. Date : 1985 Aug

PMID : 4025577






2 Functional Relationships(s)
Download
Sentence
Compound Name
Protein Name
Organism
1 A maternal placental blood flow of less than 200 ml X min-1 X kg fetal wt-1 produces a steady-state value of oxygen tension in the fetal ascending aorta of less than 17 mmHg, which is incompatible with normal oxygen delivery. Oxygen CD59 molecule (CD59 blood group) Homo sapiens
2 A minimal value of umbilical flow providing an adequate oxygen supply to the fetal body is 87 ml X min-1 X kg fetal wt-1. Oxygen CD59 molecule (CD59 blood group) Homo sapiens